date : 2022-01-01
language_code : en
name : n27co2bonbonne
ph : Not available
euh_codes
expositions
code: H280 exposition: danger: Label elements for gases under pressure text: Contient un gaz sous pression; peut exploser sous l’effet de la chaleur.
h_codes
H280
information
p_codes
P403
precautions
code: P403 text: Stocker dans un endroit bien ventilé.
age : 4
body
skin : • In case of frostbite, spray the affected area with water for at least 15 minutes. • Apply a sterile dressing. • Obtain medical assistance.
eyes : • Immediately flush the eyes thoroughly with water for at least 15 minutes.
ingestion : • Ingestion is not considered a potential route of exposure. (No specific first‑aid action required.)
inhalation : • Remove the victim to an uncontaminated area wearing a self‑contained breathing apparatus. • Keep the victim warm and rested. • Call a doctor. • Perform cardiopulmonary resuscitation if breathing stops.
company
name : AIR LIQUIDE BeNeLux
fire
water : True
foam : False
powder : False
co2 : False
other : -
labellings
explosive : False
flammable : False
oxidising : False
gaz : True
corrosive : False
acute : False
health : False
serious : False
hazardous : False
warning : Attention
protection
skin : Working gloves \| **EN 388 – Protective gloves against mechanical risk, performance level 1 or higher** \| • Minimum abrasion resistance (level 1).
Cold‑insulating gloves \| **EN 511 – Cold insulating gloves** \| • Designed for protection against cold burns/frostbite when handling liquid CO₂.
eyes : Safety goggles \| **EN 166 – Personal eye‑protection – specifications** \| • Full‑face coverage, impact‑resistant lenses.
respiratory : Self‑contained breathing apparatus (SCBA) \| **EN 137 – Self‑contained open‑circuit compressed air breathing apparatus with full face mask** \| • Provides a safe breathing environment in oxygen‑deficient atmospheres.
Positive‑pressure airline with mask (alternative) \| – \| • Used when SCBA is not available; provides positive‑pressure protection against gas ingress.
hands : Working gloves \| **EN 388 – Protective gloves against mechanical risk, performance level 1 or higher** \| • Minimum abrasion resistance (level 1).
Cold‑insulating gloves \| **EN 511 – Cold insulating gloves** \| • Designed for protection against cold burns/frostbite when handling liquid CO₂.
clothing : -
stability
stability : Stable under normal conditions
reaction : No reactivity hazard other than the effects described in the sub‑sections below.
state
state : Gas
form : Not specified as a fine powder, powder, grains, granules, pellets, viscous liquid, or paste.
storage
safe_handling : - Do not breathe the gas. - Avoid release of the product into the work area. - Handle the gas only with good industrial hygiene and safety procedures. - Only experienced and properly instructed persons should handle gases under pressure. - Consider pressure‑relief device(s) in gas installations. - Ensure the complete gas system is (or is regularly) checked for leaks before use. - Do not smoke while handling the product. - Use only properly specified equipment which is suitable for this product, its supply pressure and temperature. - Contact your gas supplier if in doubt. - Avoid suck‑back of water, acid and alkalis. - Containers that have contained flammable or explosive substances must not be inerted with liquid CO₂; potential production of solid CO₂ particles must be ruled out. - Ensure the system is adequately grounded to avoid electrostatic discharge. - Be aware of the risk of static electricity with CO₂ extinguishers; do not use them where a flammable atmosphere may be present. - Protect containers from physical damage; do not drag, roll, slide or drop them. - Do not allow back‑feed into the container. - When moving cylinders, use a cart (trolley, hand truck, etc.) designed to transport cylinders. - Leave valve protection caps in place until the container has been secured against a wall, bench or placed in a container stand and is ready for use. - If you experience difficulty operating the valve, discontinue use and contact the supplier. - Never attempt to repair or modify container valves or safety‑relief devices. - Report damaged valves immediately to the supplier. - Keep container valve outlets clean and free from contaminants, especially oil and water. - Replace valve outlet caps or plugs and container caps where supplied as soon as the container is disconnected from equipment. - Close the container valve after each use and when empty, even if still connected to equipment. - Never attempt to transfer gases from one cylinder/container to another. - Never use direct flame or electrical heating devices to raise the pressure of a container. - Do not remove or deface labels provided by the supplier for the identification of the content of the container. - Prevent suck‑back of water into the container. - Open the valve slowly to avoid pressure shock. - Keep containers stored in the vertical position and properly secured to prevent them from falling over.
safe_storage : - Observe all regulations and local requirements for storing containers. - Do not store containers in conditions that could encourage corrosion. - Keep valve guards or caps in place. - Store containers in the vertical position and secure them to prevent falling. - Periodically check containers for general condition and leakage. - Keep containers below 50 °C in a well‑ventilated place. - Store containers in a location free from fire risk and away from sources of heat and ignition. - Keep containers away from combustible materials. **Potential incompatibilities** - Containers that have contained flammable or explosive substances must not be inerted with liquid CO₂; solid CO₂ particles must be ruled out. - For detailed compatibility information, refer to ISO 11114.
specific_end_use : - Industrial and professional uses (perform risk assessment prior to use). - Test gas / Calibration gas. - Purge gas, diluting gas, inerting gas. - Purging. - Shield gas for welding processes. - Use for manufacture of electronic/photovoltaic components. - Laboratory and process control.
transport
ADR : 2
RID : 2
ADN : not available
IMDG : 2.2
IATA : 2.2
UN : 1013
Validations
Product
name : Product
role : Check if the product is compliant with all the validators
information
No information available
missing_codes
overall_result : INVALID
reference_data : None
result : INVALID
ProductLoad
name : ProductLoad
role : Check if the product information has been retrieved correctly
information
WARNING : Substances without CAS or EC numbers are omitted
missing_codes
reference_data : None
result : UNKNOWN
Exposure
name : Exposure
role : Checks the Substance exposure and labeling data. see https://echa.europa.eu/documents/10162/2324906/clp_labelling_en.pdf/89628d94-573a-4024-86cc-0b4052a74d65 see https://echa.europa.eu/regulations/clp/clp-pictograms
information
H280 : code: H280 exposition: danger: Label elements for gases under pressure text: Contient un gaz sous pression; peut exploser sous l’effet de la chaleur.
missing_codes
reference_data : None
result : AVAILABLE
Labeling
name : Labeling
role : Checks the Substance labeling data. see https://echa.europa.eu/documents/10162/2324906/clp_labelling_en.pdf/89628d94-573a-4024-86cc-0b4052a74d65 see https://echa.europa.eu/regulations/clp/clp-pictograms
information
pictograms
GHS04
signal_word : Warning
missing_codes
reference_data : None
result : AVAILABLE
Precautionary
name : Precautionary
role : Checks the Substance exposure and labeling data. see https://echa.europa.eu/documents/10162/2324906/clp_labelling_en.pdf/89628d94-573a-4024-86cc-0b4052a74d65 see https://echa.europa.eu/regulations/clp/clp-pictograms
information
P403 : code: P403 text: Stocker dans un endroit bien ventilé.
missing_codes
reference_data : None
result : AVAILABLE
PCode
name : PCode
role : Check if the P-codes of a product are valid based on its H-codes
information
Reference Codes : P410 + P403
Actual Codes : P403
Codes in both sets :
reason : The result is invalid because there are codes in the reference data but not in the actual data
Missing Codes : P410 + P403
missing_codes
P410 + P403
reference_data : None
result : INVALID
Classification
name : Classification
role : Check the classification of a product based on its pH and substances concentrations
information
No information available
missing_codes
reference_data : None
result : VALID
Carbon dioxide
cas : 124-38-9
ec : 204-696-9
name : Carbon dioxide
h_codes
H280
concentrations : greater or equal to 100.0 and less or equal to 100.0
Validations
HazardStatement
name : HazardStatement
role : Check if the H-codes of a substance are valid based on its CAS number by comparing them to a reference data set from ECHA CLH
information
Reference Codes :
Actual Codes : H280
Codes in both sets :
reason : The result is valid because all codes from the reference data are found in the actual data
missing_codes
result : VALID
POP
name : POP
role : Check if the product must be compliant with the POP regulations
information
No information available
missing_codes
result : NOT_REGULATED
REACH
name : REACH
role : Check if the product must be compliant with the REACH regulations according to REACH Annex XVII and XIV
information
No information available
missing_codes
result : NOT_REGULATED
COBET
name : COBET
role : Check if the product must be compliant with the COBET regulations
information
vle-ppm : 5000.0
vle-mg-m3 : 9131.0
vle-courte-ppm : 30000.0
vle-courte-mg-m3 : 54784.0
missing_codes
result : REGULATED
RPB
name : RPB
role : Check if the product must be compliant with the RPB regulations
information
regulation : RPB
substance : Carbon dioxide
entries : 4
missing_codes
result : REGULATED
SEVESO
name : SEVESO
role : Check if the product must be compliant with the CEVESO regulations
information
No information available
missing_codes
result : NOT_REGULATED
Exposure
name : Exposure
role : Checks the Substance exposure and labeling data. see https://echa.europa.eu/documents/10162/2324906/clp_labelling_en.pdf/89628d94-573a-4024-86cc-0b4052a74d65 see https://echa.europa.eu/regulations/clp/clp-pictograms
information
H280 : code: H280 exposition: danger: Label elements for gases under pressure text: Contient un gaz sous pression; peut exploser sous l’effet de la chaleur.
missing_codes
result : AVAILABLE
Labeling
name : Labeling
role : Checks the Substance labeling data. see https://echa.europa.eu/documents/10162/2324906/clp_labelling_en.pdf/89628d94-573a-4024-86cc-0b4052a74d65 see https://echa.europa.eu/regulations/clp/clp-pictograms
information
pictograms
GHS04
signal_word : Warning
missing_codes
result : AVAILABLE
INRS
name : INRS
information
fiche : FICHEJuin 2020Fiche n°238 - Dioxyde de carboneFiche présentant l'essentiel des données d'hygiène et de sécurité relatives à« Dioxyde de carbone »avec un rappel de la réglementation française et des recommandations techniques et médicales.En savoir plus
url : https://www.inrs.fr/accueil/publications/bdd/fichetox/fiche.html?refINRS=FICHETOX_238
sections
Généralités, Caractéristiques, VLEPMesurage, Incendie - Explosion, Pathologie - Toxicologie, Règlementation, Recommandations, Bibliographie
missing_codes
result : AVAILABLE
role : None
CMR
name : CMR
role : Check if the product must be compliant with the CMR regulations
information
No information available
missing_codes
result : NOT_REGULATED